Filtration class: G3~M5
Filter media: Double-layer synthetic fiber
Structure: Diversified structural design to adapt to the needs of various application scenarios
Continuous operating temperature: ≤68℃
Recommended final resistance: ≤250 Pa
Main applications: Suitable for pre-filtration devices in the air intake and exhaust systems of air conditioning units for various high-speed trains, subways, Shinkansen carriages and cabs.
Features: Low initial pressure drop, long service life, and particulate matter removal efficiency >90%
Rail Transit Field
Air Guard’s CleanWay series products ensure air quality in public transportation
Rail Transit Field Solution
The air pollution in rail transit systems is extremely severe.
In rail transit scenarios with daily passenger flows reaching tens of millions, microbial pollution in enclosed spaces, metal dust, and tail gas particles pose complex air threats. Relying on in-depth understanding of rail transit operation characteristics, Air Guard has developed a physical barrier-type primary-middle efficiency integrated filtration solution. It achieves high-efficiency low-resistance filtration, effectively intercepts infectious aerosols, and provides comprehensive air purification for rail transit—committed to safeguarding every trip.
Air Guard CleanWay series delivers reliable technical solutions for rail transit.
Compared with traditional electronic filters, CleanWay physical barrier-type primary-middle efficiency integrated filters offer distinct advantages:
No ozone generation, protecting passengers’ and staffs’ respiratory health.
No microbial mutation promotion, avoiding genetic variation risks.
No corrosive gases, harmless to equipment and environment.
No electromagnetic interference, ensuring stable signal operation.
Easy installation & maintenance, reducing costs and improving efficiency.
Air Guard’s rail transit filtration solution, uniquely designed for the industry, combines high efficiency with low resistance. Its physical barrier technology effectively intercepts infectious aerosols to meet the highest air quality standards. Unlike electronic filters, it eliminates ozone, microbial mutation, corrosive gases, and electromagnetic interference—ensuring every breath is safe.

Air Guard’s Practical Application Solutions and Advantages——Case Analysis of Dongguan Metro Line 2:
Case Background
With the rapid development of urban transportation systems, metro, as an important public transport, sees the air quality in carriages directly affect passengers’ health and comfort. To address this challenge, Air Guard Purification Technology Group provided a customized air purification solution for Dongguan Metro Line 2.
Solutions and Implementation
Air Guard’s air filtration and purification product units adopt the most advanced filtration technologies and innovative design schemes. These technologies include nano-level high-efficiency filters, which can effectively capture and intercept harmful substances in the air, such as particulates and bacteria. Combined with high-performance negative ion generator units and working together with the air conditioning fresh air circulation system, they achieve efficient purification of the turbid air in carriages.
In particular, Air Guard’s specially designed air conditioning filters for rail transit can not only efficiently filter harmful substances such as particulates, formaldehyde, and VOCs (volatile organic compounds) in metro carriages, but also intercept metal dust and iron particles entering the carriages, and inhibit the growth of microorganisms such as bacteria and viruses. This comprehensive protection measure significantly reduces the risk of pathogen transmission through aerosols in crowded crowds.
In addition, Air Guard’s technical team also highlights the energy-saving features of its products. By optimizing filter materials, improving product structure, and reducing air resistance, Air Guard’s products not only ensure high-efficiency filtration but also significantly reduce energy consumption and carbon emissions. For example, the surface of the innovative filter material is treated with hydrophobicity, which helps prevent the formation of water films due to the humid underground environment during high-speed train operation, maintains sufficient ventilation performance, and thus reduces air conditioning energy consumption and operational maintenance costs.
Practical Effects and Advantages
Air Guard’s air purification solution has achieved remarkable results in Dongguan Metro Line 2:
Improved Air Quality: Greatly enhanced the air quality in carriages, ensuring passengers’ breathing safety and health.
Enhanced User Experience: A fresh and healthy air environment significantly improves passengers’ riding experience.
Energy Conservation and Emission Reduction: The optimized filtration system helps reduce energy consumption, in line with the concept of green development.
Simplified Maintenance Process: The design for easy cleaning and replacement reduces maintenance costs and time, avoiding secondary pollution possibly caused by maintenance personnel during filter cleaning.
Environmental Contribution: Through energy-saving and environmental-friendly design, Air Guard helps enterprise users save energy costs and promotes the development of low-carbon green industries.


Surface Painting Field Related Productions
Coarse Efficiency Panel Filter

Pleated Filter Media
Filtration Class: G4-F8
Filter Media: High-performance synthetic fiber with anti-fracture property
Structure: Graded structure with adhesive-treated filter cotton, permanently retaining captured particles throughout service life
Continuous Operating Temperature: ≤100℃
Main Applications: High-speed rail, subway, light rail, intercity rail; 100% capture of dust particles >10μm
Compliance: DIN5510:2:S4\ST2\SR2

High-Efficiency Filter
Filtration class: CN95-level high-efficiency filtration of fine particles and other pollutants in the air to provide clean air for carriages
Filter media: Double-layer synthetic fiber
Structure: Designed for the unique application environment of rail transit, it can effectively filter heavy metal dust pollution and intercept aerosols and droplet nuclei carrying various influenza, pneumonia and other viruses transmitted between passengers through the respiratory system in the air, reducing the risk of disease transmission
Continuous operating temperature: ≤70℃
Recommended final resistance: ≤250 Pa
Main applications: Suitable for air conditioning systems of various high-speed trains, subways, Shinkansen carriages and cabs

Previous