Filtration Grade: G2
Filter Media: Three-dimensional folded metal mesh
Structure:
Multi-layer corrugated filter screens stacked in a crisscross pattern
Continuous Operating Temperature: ≤300℃
Resistance: ≤10Pa
Recommended Service Life:
Suitable for use in harsh environments, can be cleaned multiple times without replacement
Main Application:
Prefiltration at the front-end wall of fresh air systems to block large particles such as insects, rodents, leaves, and pollen
Commercial Complex Field
Air Guard CleanSmooth Series Products prevent
Commercial Complex Field Solution
Hazards of Indoor Air Pollution in Commercial Buildings
Indoor air quality in commercial buildings (such as offices, shopping malls, hotels, hospitals, etc.) directly affects occupants’ health, comfort, and work efficiency. A Harvard University study found that reducing indoor concentrations of particulate matter (PM2.5) and volatile organic compounds (VOCs) significantly improves employees’ cognitive functions—including decision-making ability and information processing speed.
Particulate Matter Pollution
Outdoor haze, vehicle exhaust, and printer dust can cause respiratory diseases and allergic reactions. Prolonged exposure may trigger cardiovascular issues.
Microbial Contamination
Bacteria, viruses, and mold can lead to influenza, allergies, and asthma—particularly severe in hotels.
Volatile Organic Compounds (VOCs)
Emissions from building materials, furniture, and cleaners cause headaches and nausea. Long-term exposure may damage the liver and nervous system.
Odor Pollution
In environments with better air quality, employees’ cognitive function scores improved by 61%.
Air Guard CleanSmooth Series: Reliable Technical Solutions for Commercial Buildings
The Air Guard CleanSmooth series of air purification filters addresses indoor air pollution hazards in commercial buildings. Our filters adopt multi-layer filtration designs to efficiently remove particulates, microbes, and VOCs, ensuring air quality meets international standards (e.g., ISO 16890, EN 1822).
Key Features:
Multi-Layer Filtration System
Integrated with fresh air systems to maintain indoor air freshness and enhance customer shopping experiences.
Combination of Diverse Filters
Gradual filtration of particles by Air Guard Prefilters (G4), Medium-Efficiency Filters (F7-F9), and HEPA Filters (H13/H14) based on particle size.
High-Efficiency Antibacterial & Antiviral Capability
HEPA filters and antibacterial/anti-allergy materials effectively intercept bacteria, viruses, and mold, reducing disease transmission risks.
Fresh Air System Integration
Ensures indoor air circulation and cleanliness, reduces carbon dioxide concentration, and enhances air freshness.

Air Guard’s Practical Application Scheme and Advantages: Case Analysis of Dongguan Rural Commercial Bank:
Case Background
Air Guard installed its self-developed integrated fragrance combination (antibacterial, antiviral, high-efficiency, low-resistance) air purification filter for the central air conditioning return air vents at the Wangniudun Sub-branch of Dongguan Rural Commercial Bank. The introduction of this innovative product aims to address poor indoor air quality in the bank’s business hall, particularly considering the space’s relatively enclosed, densely populated, and high-traffic characteristics.
Air Quality Challenges Faced by the Bank
As a public space with frequent foot traffic, the bank’s business hall faces not only conventional air pollution issues such as PM2.5 and VOC (volatile organic compounds) gaseous pollutants but also special contamination from bacteria carried by banknotes. On average, each one-yuan RMB note carries up to 1.18 million bacteria, which suspend and accumulate in the air, leading to a rise in harmful microbial concentration and increasing the risk of epidemic diseases spreading through the air. Prolonged exposure to such an environment may damage the respiratory and cardiovascular health of staff and customers.
Solution Introduction
To address the above issues, Air Guard proposed a solution: equipping the central air conditioning system in public places with an “N95 mask.” Specifically, this involves installing air filters at the return air vents of the central air conditioning system to intercept PM2.5, VOC gaseous pollutants, and harmful microorganisms such as bacteria, viruses, and mold. This reduces the concentration of harmful substances in indoor air, minimizes human inhalation of toxic materials, and thereby lowers the risk of disease transmission through the air, protecting public respiratory health. Air Guard’s air purification filters for commercial buildings feature:
High-efficiency Filtration: Achieves multi-stage filtration through the special structure of filter media, with an effective filtration area 2.5 to 3 times that of ordinary filters. Tested according to GB/T 18801 standards, the filtration efficiency reaches 99% after 60 minutes of cyclic filtration.
Low-resistance Design: Adopts a unique pleated design for air circulation, ensuring minimal resistance during operation without affecting indoor air flow or comfort.
Antibacterial & Antiviral: Intercepts over 99% of common pathogens such as E. coli, Staphylococcus aureus, Candida albicans, and H1N1 influenza virus.
Plant Fragrance Slow-release Technology: Incorporates patented plant fragrance slow-release technology to effectively control fragrance concentration, extend release time, and create a pleasant and comfortable experience.
Implementation Effects
Since implementation, Air Guard’s air purification filters have significantly improved indoor air quality at the Wangniudun Sub-branch of Dongguan Rural Commercial Bank, creating a healthier working environment. Staff work efficiency has increased, and customer satisfaction has followed suit. Additionally, reducing the risk of diseases caused by poor air quality has indirectly lowered medical costs and absenteeism rates.


Commercial Complex Field Related Productions
G2 Grade Filter

Coarse Panel Filter
Filtration Grade: G3~M5
Filter Media: Double-layer Synthetic Fiber
Structure:
Diversified structural design to meet the needs of various application scenarios.
Continuous Operating Temperature: ≤68℃
Recommended Final Resistance: ≤250 Pa
Main Application:
Suitable for pre-filtration devices in the intake and exhaust systems of air conditioning unit ventilation.
Features:
Low initial pressure drop, long service life, particle removal efficiency >90%.

Bag Filter
Filtration Grade: G4~M6
Filter Media: Double-layer Synthetic Fiber
Structure:
Filter bags with ultrasonic welding technology, self-supporting filter bags
Continuous Operating Temperature: ≤70℃
Recommended Final Resistance: ≤250Pa
Features:
Low initial pressure drop, long service life, high efficiency, high dust holding capacity
Main Application:
Suitable for pre-filtration devices in ventilation intake systems

Bag Filter
Filtration Grade: M5 – F8
Filter Media: Multi – layer Fluffy Synthetic Fiber Cotton
Structure: Triangular “V” – shaped Segmentation and Suture Technology
Continuous Operating Temperature: ≤68℃
Recommended Final Resistance: ≤450 Pa
Main Application: Suitable for the main filter of the air – conditioning box ventilation system.
Features: Low initial pressure drop, long service life, particle removal efficiency > 95%.

Coarse Plate Filter
Filtration Grade: M6~F9
Filter Media: Nanofiber Layer
Structure: Corrugated Deep-bed Filtration Design
Continuous Operating Temperature: ≤68℃
Recommended Final Resistance: ≤450 Pa
Fire Resistance Test: F1 DIN53438
Main Application: Suitable for the main filter of air-conditioning box ventilation systems
Features:
Corrugated nanofiber layer effectively reduces resistance, deep-bed filtration increases dust holding capacity, and efficiency remains stable.

Medium to High-Efficiency Panel Filter
Filtration Grade: M5~F9
Filter Media: Glass Fiber Material
Structure:
Partitionless tightly pleated panel structure
Continuous Operating Temperature: ≤68℃
Recommended Final Resistance: ≤350Pa
Main Application:
Suitable for air conditioning systems with high air volume and limited installation space.
Features:
Low resistance, suitable for large air volume, long service life.
Particle removal efficiency >90%.

Gas Adsorption Activated Carbon Module
High-Concentration Pollution, Long-Life Molecular Filter
Filter Media:
Activated carbon, impregnated activated carbon, impregnated activated alumina
Structure:
“V”-shaped ABS and PET outer frame
Optimal Continuous Operating Temperature: 10-45℃
Optimal Continuous Operating Humidity: 40-90%
Main Application:
Suitable for high-concentration polluted and corrosive gases in electronic and electrical equipment.
Features:
Materials can be selected according to different application scenarios and gas treatment requirements.

High – efficiency and Low – resistance Fragrance Filter
Filter Media: Self – developed Fragrance – infused Synthetic Fiber Filter Material
Structure: Plate – type Dense – fold
PM2.5 Efficiency: ≥99.95%
Continuous Operating Temperature: ≤68℃
Fragrance Duration: > 6 months with no resistance reduction
Main Application: Suitable for commercial air – conditioning outlets to provide clean and comfortable air.

Multi-Effect Composite Fresh Air Filter
Filter Materials:
Antibacterial layer
Chemical adsorption layer
High-efficiency particulate matter capture layer
Structure:
Plate-type dense fold design
Performance Indicators:
Antibacterial and anti-allergy efficiency: >95%
PM2.5 filtration efficiency: ≥99.95%
Continuous operation temperature: ≤68℃
Main Applications:
Suitable for commercial air conditioning air outlets to provide clean and comfortable air.